Please click below to download a PDF copy of the flyer. Note that AWC, Inc. shall not be responsible for statements or opinions contained in papers or printed in publications.
Shared Goals:
Safe, Effective Operations
Shared Commitment:
Caring for People, High Quality,
Fast Service
Certified Resources:
400 Engineers, Technical Support
& Service Specialists

Pressure Management Network
Life Cycle Management
- PRV Inventories (AWC > $4M, Farris FAST Centers $12M)
- Farris FAST Authorized Assembler TechnicianTraining/Certification
- AWC Level I & II Technician Training/Certification
- Cross Location Consistent Tooling/Test Equipment/Inventories
- PRV Sizes from 1/2” - 16”
- Sec I (Steam) New Valve Build (V Certified)
- Sec I (Steam) New Valve Build (V Certified)
- Tank Vent/Emergency Hatch (Industry Standard Designs) 1” -36”
- Valve Walk Down and Pre-Assessments
- Pilot Operated Tank Vent Repair
- On-site PRV Test/Repair Trailers and Equipment
- 25 Foot (2X)
- 53 Foot
- Accutest (In situ test device)
- Load/Capacity Truck Fleet
- Pickup/Delivery
- Service/Tools/Equipment
- Spares Pool Management
- Inventory Management
- Workforce Management
- Equipment and Facility Capacity Planning
- Online Access to Valve Status and Travelers including Pre-Test Results for Optimizing Proof Test Cycles for Process Safety Management Programs (PSM)
- PHA Integration and Augmentation - Farris Engineering Service, iPRSM


Deer Park (Texas)
- 23,000 sq/ft
- 4 Test Benches (Equipped with Air Test Drum & Water J-Tube)
- 1Boiler (2850psig)
- 1 Dedicating Lapping Room
- 7 Work Stations
- 1 Permitted Paint Booth
- 3 Sand / Bead Blasters (2 arm-in, 1 rotablaster)
- 2 Five Ton Overhead Cranes
- 3 One Ton Gorbel Gantry Cranes
- 2 Field Service Trailers
- >$3 Million in PRV / Valve Inventory
Freeport (Texas)
- 3,000 sq/ft
- 1 Test Bench (Equipped with Air Test Drum & Water J-Tube)
- 1 Dedicated Lapping Table
- 1 Pressure / Vacuum Vent Test Bench
- 2 Work Stations
- 1 Permitted Paint Booth
- 2 Sand / Bead Blaster (2 arm-in)
- Field Service Trailers
- PRV Repair Inventory
Port Arthur (Texas)
- 3,000 sq/ft
- 1 Test Bench (Equipped with Air Test Drum & Water J-Tube)
- 1 Boiler (900psig)
- 1 Dedicated Lapping Table
- 1 Pressure / Vacuum Vent Test Bench
- 1 Permitted Paint Booth
- 2 Sand / Bead Blasters (2 arm-in)
- 1 Ten Ton Overhead Crane
- 1 Two Ton Gorbel / Gantrey Crane
- Field Service Trailers
- >$500K in PRV / Valve Inventory
Corpus Christi (Texas)
- 9,000 sq/ft
- 1 Test Bench (Equipped with Air Test Drum & Water J-Tube)
- 1 Boiler (1750psig)
- 1 Dedicated Lapping Table
- 1 Pressure / Vacuum Vent Test Bench
- 4 Work Stations
- 1 Permitted Paint Booth
- 2 Sand / Bead Blasters (1 arm-in, 1 rotablaster)
- 1 Five Ton Overhead Crane
- 2 One Ton Gorbel Gantry Cranes
- Field Service Trailers
- >$500K in PRV / Valve Inventory
Lake Charles (Louisiana)
- 15,000 sq/ft
- 1 Test Bench (Equipped with Air Test Drum & Water J-Tube)
- 1 Dedicated Lapping Table
- 2 Work Stations
- 1 Permitted Paint Booth
- 1 Sand / Bead Blaster (1 arm-in)
- 1 Gorbel / Gantrey Crane
- Field Service Trailer
- >$200K in PRV / Valve Inventory
Baton Rouge (Louisiana)
- 20,000 sq/ft
- 1 Test Benches (Equipped with Air Test Drum & Water J-Tube)
- 1 Boiler (1750psig)
- 1 Oxygen Clean Room
- 1 Dedicated Lapping Table
- 2 Work Stations
- 1 Permitted Paint Booth
- 2 Sand / Bead Blasters (2 arm-in, 1 roto blaster)
- 1 Five Ton Gorbel / Gantry Crane
- Field Service Trailer
- >$500K in PRV / Valve Inventory